Many homeowners wonder, “What size generator do I need to run my air conditioner?” Choosing the correct generator size is crucial to keep your home cool during power outages, especially in areas prone to heatwaves. This guide explains the factors that determine generator size, breaks down AC power requirements, and provides practical tips for safe, reliable backup power.
AC Unit Size | Typical Running Watts | Typical Starting Watts | Suggested Generator Size |
---|---|---|---|
Window (5,000–8,000 BTU) | 400–900 | 900–1,600 | 2,000–2,500 watts |
Window (10,000–15,000 BTU) | 900–1,500 | 1,800–3,000 | 3,000–5,000 watts |
Central AC (2 ton/24,000 BTU) | 3,500 | 7,000–8,000 | 8,000–10,000 watts |
Central AC (3–5 ton/36,000–60,000 BTU) | 4,500–6,000 | 9,000–12,000 | 12,000–20,000 watts |
Why AC Units Need The Right Generator Size
Air conditioners have high start-up power requirements. Selecting a generator that meets both starting and running watts is vital for consistent operation. Undersized generators may trip, overheat, or fail to power your AC, while oversized units cost more and waste fuel.
Understanding Generator And AC Power Terms
To answer, “what size generator do I need to run an air conditioner”, it’s crucial to understand power terminology:
- Running Watts: Power needed to keep the AC running continuously.
- Starting (Surge) Watts: Extra power needed for a few seconds when the AC starts up.
- BTU (British Thermal Unit): Indicates cooling capacity. More BTUs generally require more watts.
- Amperage & Voltage: Some ACs list amps and volts instead of watts. Multiply amps x volts to get wattage.
Always choose a generator that provides at least as much starting wattage as your AC’s requirement.
Calculating Your Air Conditioner’s Power Needs
Follow these steps to figure out what size generator is best for your air conditioner:
-
Locate The AC Unit’s Data Plate Or Manual:
This will specify either wattage or amps and voltage. If only amps and volts are given, multiply them for total watts: Watts = Volts x Amps.
-
Account For Starting (Surge) Watts:
Many AC units require 2-3 times their running watts during startup. Be sure your generator can handle this temporary surge.
-
Factor In Other Appliances:
If you want to power more than just the air conditioner, add their wattages to your total. Prioritize critical items (fridge, lights, sump pump, etc.).
-
Match With Generator Output:
Choose a generator with a rated (running) watt output that meets or exceeds your calculated needs.
Typical Generator Sizes For Different Types Of Air Conditioners
Window Air Conditioner Units
Most U.S. window ACs range from 5,000 to 15,000 BTUs. Smaller models can run on portable generators as low as 2,000 watts. Larger window units (12,000–15,000 BTUs) may need a 3,500–5,000-watt generator to allow for high start-up surges and operation of essential household devices.
Portable And Mini-Split AC Systems
Portable air conditioners and ductless mini-splits have power demands similar to large window units. Expect a minimum requirement of 2,000–3,500 watts for smaller models and 4,000–6,000 watts for larger units. Inverter generators are popular for these due to their efficiency and quiet operation.
Central Air Conditioning Systems
Central AC units, especially in homes over 1,500 sq. ft., are the most demanding. A 2-ton central AC (24,000 BTUs) usually requires about 7,000–10,000 watts for startup, settling into 3,500–4,000 running watts. Larger 3–5 ton systems can demand startup surges up to 12,000 watts or more.
For most homes, a whole-house generator in the 12,000–20,000 watt range is the safest choice for central AC plus other essentials.
Example Scenarios: Generator Size Selection
Scenario 1: Small Apartment With A Window AC
- AC: 8,000 BTU Window Unit
- Running watts: 800
- Starting watts: 1,600
- Other loads (fridge, lights): 1,000 watts
Total minimum generator size: 2,500–3,000 watts
Scenario 2: Medium Home With A 2-Ton Central AC
- AC: 24,000 BTU central unit
- Running watts: 3,500
- Starting watts: 7,500
- Other essential loads: 2,000 watts
Total minimum generator size: 10,000 watts recommended
Scenario 3: Large Home With A 4-Ton Central AC
- AC: 48,000 BTU system
- Running watts: 6,000
- Starting watts: 11,500
- Other loads (well pump, appliances): 4,000 watts
Total minimum generator size: at least 15,000–18,000 watts
How To Reduce Generator Size Needs For Your AC
Lowering the initial surge requirement and running load helps you use a smaller, more affordable generator. Strategies include:
- Soft Start Kits: Many new ACs support “soft start” or hard start kits, which dramatically reduce start-up surge. Ask your HVAC technician for compatibility.
- Stagger Appliance Startup: Don’t start multiple heavy appliances at once. Let the air conditioner reach running speed before turning on other devices.
- Prioritize Essentials: During outages, run only necessary equipment, and cycle use of large appliances.
- Regular AC Maintenance: Efficient, clean AC units draw less power and start more easily.
Portable Vs. Standby Generators: Pros And Cons For AC Use
Generator Type | Pros | Cons |
---|---|---|
Portable generators (3,000–10,000 watts) |
|
|
Whole-house standby (10,000–25,000+ watts) |
|
|
Essential Features To Look For In A Generator For Air Conditioning
- High Surge Capacity: Generator must support high startup loads for your AC unit.
- Automatic Voltage Regulation (AVR): Protects sensitive electronics in the AC.
- Fuel Type And Runtime: Longer outages need larger fuel tanks or hookups to LP/natural gas.
- Secure Outlets Or Transfer Switches: Make sure your generator can safely connect to the AC circuit—with professional installation for central units.
- Inverter Technology (Optional): For very sensitive electronics or variable motor speeds, inverter generators provide smoother power and quieter operation for window and portable ACs.
Generator Sizing Mistakes Homeowners Should Avoid
- Ignoring Starting Watts: Don’t size a generator by running watts alone; always include start-up surge.
- Overloading Circuits: Plugging in too many heavy appliances risks tripping breakers or damaging equipment.
- Improper Connection: Never connect a generator directly to home wiring without a transfer switch. Dangerous backfeeding can occur.
- Not Considering Expansion: Future-proof your choice; consider potential AC or home upgrades when selecting generator size.
- Failure To Maintain AC & Generator: Both systems need regular care for reliable operation during emergencies.
Fuel Type Considerations For Generators Powering Air Conditioners
The choice of generator fuel (gasoline, propane, natural gas, diesel) impacts runtime, startup reliability, and long-term costs.
- Gasoline: Widely available but short runtime; best for short outages and portable units.
- Propane (LPG): Cleaner burning, storable indefinitely, supports larger portable or standby generators.
- Natural Gas (NG): Ideal for permanent standby systems, unlimited runtime as long as supply is uninterrupted.
- Diesel: Efficient for large homes/facilities, long runtime, but requires dedicated storage and regular maintenance.
Standby generators (for central ACs) are most often fueled by natural gas or propane, offering automatic, hassle-free backup.
Can A Generator Power HVAC Units With Heat Pumps Or Dual-Fuel Systems?
Many modern HVAC systems include both air conditioning and heating (heat pump) in one package. These systems may require even higher startup surges compared to AC-only units. Always check the manufacturer’s specifications and consider consulting an electrician or HVAC specialist before generator installation for combined cooling/heating systems.
Professional Installation And Safety Tips
- Use Licensed Electricians: Connecting generators to home and AC circuits—especially for central systems—should be done by professionals. This ensures code compliance and safety.
- Follow All Manufacturer Guidelines: Check both generator and AC manuals for safe operational procedures.
- Never Operate Indoors: Generators must be run outdoors, away from windows and vents, due to deadly carbon monoxide risk.
- Allow For Proper Cooling: Generators work hard when running ACs. Follow prudent duty cycles and ensure adequate ventilation around the unit.
Cost Estimates For Generators Sized For Air Conditioners
Generator Type | Accommodates | Approximate Cost |
---|---|---|
2,000–3,500 watt portable | Small window/portable AC, some lights | $350–$700 |
5,000–8,000 watt portable | Large window AC, fridge, lights, few other appliances | $800–$1,400 |
10,000–12,000 watt portable | Small central AC, essential circuits | $1,500–$2,500 |
12,000–22,000 watt standby | Whole-house, central AC up to 5 tons | $4,000–$8,000 installed |
Prices are approximate and vary based on brand, installation needs, and regional labor rates.
Trusted Brands Of Generators For Air Conditioners
- Generac: Leading choice for whole-house standby units.
- Honda: Renowned for portable inverter models (quiet, fuel-efficient for window and portable ACs).
- Champion Power Equipment: Affordable and reliable portable generators.
- Kohler: High-quality standby solutions for home and business.
Always match generator ratings with your AC specifications for best results.
Frequently Asked Questions About Generator Size For Air Conditioning
Can I Use My Portable Generator With My Central AC?
It is possible, but most portable generators lack the power to handle central systems. For smaller (2-ton) central units, a powerful 10,000–12,000 watt portable generator may suffice if started properly and loads are staggered.
What Happens If The Generator Is Too Small?
If the generator is undersized, the air conditioner may fail to start, shut off unexpectedly, or the generator could overheat, risking damage. Always exceed minimum requirements for safety and reliability.
Is It Better To Oversize The Generator?
It’s generally best to have a margin above your estimated needs, but excessive oversizing wastes money, fuel, and space. Aim for around 20% more capacity than your measured surge loads.
Do I Need To Hire A Professional?
For central AC or whole-home backup, professional installation is strongly advised. Portable generators for window/portable ACs can often be used with heavy-duty extension cords and proper safety precautions.
Final Recommendations For Choosing The Right Generator To Power Your Air Conditioner
- Identify your air conditioner’s running and starting wattage, then calculate the total for all items you wish to run.
- Select a generator at least 20% above this value, accounting for startup surges and extra demand in emergencies.
- Choose a portable generator for window or small portable AC, and a whole-house standby generator for central AC or larger homes.
- Consult with licensed professionals for connection to central AC or permanent installation.
With the right research and careful planning, you can select the perfect generator to keep your home cool and safe during any power outage.