Rheem Furnace Code 13: Causes, Troubleshooting and Fixes

The Rheem furnace code 13 indicates an ignition failure or flame sensing problem that prevents the furnace from lighting or maintaining a stable flame. This article explains what Rheem Furnace Code 13 means, typical causes, step-by-step troubleshooting, safety considerations, common repairs, and when to call a qualified HVAC technician.

Code Meaning Common Causes First Steps
Rheem Furnace Code 13 Ignition or Flame Sense Failure Dirty flame sensor, failed ignitor, gas supply issue, control board fault Reset power, inspect flame sensor & ignitor, ensure gas valve open

What Rheem Furnace Code 13 Means

Rheem uses diagnostic codes to communicate component or system failures. Code 13 typically signifies the furnace attempted to ignite but did not detect a flame within the expected time window or the flame sensor failed to confirm ignition. This prevents the blower and heating cycle from continuing for safety reasons.

How The Furnace Ignition Sequence Works

Understanding the ignition cycle helps diagnose Rheem Furnace Code 13. When the thermostat calls for heat, the control board initiates a sequence: draft inducer starts, pressure switch verifies airflow, the ignitor (hot surface or spark) energizes, the gas valve opens, and the flame sensor detects combustion. If any step fails, the board can lock out and display the code.

Common Causes Of Code 13

Several issues commonly trigger the code. Identifying which is present narrows repairs.

  • Dirty Or Faulty Flame Sensor: Accumulated soot or oxidation prevents proper flame detection.
  • Failed Ignitor: A cracked or worn hot surface ignitor cannot reach required temperature to light gas.
  • Gas Supply Issues: Closed gas valve, empty gas meter, or low gas pressure prevents ignition.
  • Ignition Control Or Circuit Board Fault: Electronics may fail to command the ignition sequence correctly.
  • Wiring Or Connection Problems: Loose, corroded, or broken wires between sensors, ignitor, and control board.
  • Blocked Vent Or Pressure Switch Failure: If the pressure switch or inducer fails, the control board may not proceed to ignition.

Safety First: Precautions Before Troubleshooting

Safety is essential when working on gas furnaces. Turn off power at the breaker and shut the gas supply before inspecting components. If the user smells gas, evacuate the area and call the gas utility or emergency services. When in doubt, contact a licensed HVAC technician to avoid risk of fire, explosion, or carbon monoxide hazards.

Basic Troubleshooting Steps For Rheem Furnace Code 13

These steps help identify simple causes and may resolve many Code 13 occurrences.

Call 888-906-9139 – Get Your Free HVAC Quote & Save More Today!

1. Reset The Furnace

Sometimes transient errors clear after a reset. Turn the thermostat to off, switch the furnace power off at the breaker for 30 seconds, then restore power and call for heat. If the code reappears, continue troubleshooting.

2. Check The Thermostat And Gas Supply

Confirm the thermostat settings are correct and the gas shutoff near the furnace is open. Verify other gas appliances work to rule out a meter or supply outage. Low or interrupted gas supply can prevent ignition and prompt Code 13.

3. Inspect The Flame Sensor

The flame sensor is a thin metal rod positioned in the burner flame. Turn off power and gas, remove the sensor by unscrewing its mounting, and gently clean the metal rod with fine emery cloth or 400-600 grit sandpaper to remove carbon and oxidation. Reinstall and test. Cleaning often resolves flame-sensing failures.

4. Examine The Ignitor

Inspect the hot surface ignitor for visible cracks or breaks. An ignitor that does not glow or appears damaged requires replacement. Ignitors are fragile; handle carefully and replace with the exact Rheem OEM or compatible part.

5. Check Wiring And Connections

Inspect wiring harnesses and terminal connections for corrosion, loose wires, or burn marks. Secure any loose connections and replace damaged wires. A multimeter can verify continuity and voltages per the furnace wiring diagram.

6. Verify Pressure Switch And Inducer Operation

Watch the furnace start sequence. If the inducer motor or pressure switch fails, the control board may not allow ignition. Listen for the inducer motor and look for a vacuum tube connected to the switch. Replace a faulty pressure switch or inducer motor per manufacturer guidance.

Call 888-906-9139 – Get Your Free HVAC Quote & Save More Today!

When The Issue Is Intermittent

Intermittent Code 13 problems are often caused by component degradation like a failing ignitor warming inconsistently or wiring that disconnects with vibration. Log when failures occur, environmental conditions, and whether the furnace had recent service. This pattern helps technicians pinpoint intermittent faults.

Parts Replacement: Flame Sensor And Ignitor

Replacing the flame sensor or ignitor is common for Code 13 fixes.

  • Flame Sensor Replacement: Typically affordable and user-serviceable with basic tools. Match the part number and ensure proper reinstallation to avoid false readings.
  • Ignitor Replacement: More delicate and often slightly costlier. Use anti-static precautions and avoid touching the new ignitor’s ceramic surface with bare hands.

Control Board And Electronic Failures

If sensors and ignitor test good, the control board or ignition module may be defective. Symptoms include inconsistent sequencing, no voltage to the ignitor, or error codes persisting after parts replacement. Diagnosis often requires multimeter readings and knowledge of the furnace control logic, best handled by an HVAC pro.

When To Call A Professional

Contact a licensed technician when any of the following applies: uncertainty about gas work, persistent Code 13 after basic troubleshooting, visible gas leaks, failed control board, complex wiring issues, or when warranty coverage requires authorized service. Professionals can run advanced diagnostics, test gas pressures, and safely replace electronic modules.

Costs And Time Estimates

Costs vary by region and part. Typical ranges for common fixes:

  • Flame Sensor Cleaning Or Replacement: $50–$200 including parts and labor.
  • Ignitor Replacement: $100–$350 including parts and labor.
  • Inducer Or Pressure Switch Repair: $150–$400.
  • Control Board Replacement: $300–$800 depending on model.

Simple cleaning can take 15–30 minutes. Part replacements typically require 30 minutes to 2 hours depending on access and complexity.

Preventive Maintenance To Avoid Code 13

Regular maintenance reduces ignition-related failures. Recommended actions include annual professional tune-ups, cleaning burners and flame sensors, replacing air filters, and ensuring proper venting. Periodic visual checks for corrosion or rodent damage to wiring also helps.

Interpreting Other Rheem Codes Related To Ignition

Rheem furnaces may display other codes that point to related systems like pressure switch faults or blower errors. When Code 13 appears alongside other lights or codes, document the complete sequence for the technician to expedite repair.

Documentation And Warranty Considerations

Retain furnace model and serial numbers, the control board part number, and service records. If a furnace is under warranty, using authorized service providers ensures coverage. Unauthorized modifications or repairs may void warranty protections.

DIY Checklist For Rheem Furnace Code 13

  1. Turn power and gas off before work.
  2. Reset the furnace and retest.
  3. Confirm gas supply and thermostat operation.
  4. Remove and clean the flame sensor.
  5. Inspect the ignitor for cracks and test for continuity.
  6. Check wiring, connectors, and low-voltage control circuits.
  7. Observe inducer and pressure switch during startup.
  8. Call a professional if the issue persists or if gas components need adjustment.

Resources And Further Reading

For specific diagrams, Rheem’s installation manual and homeowner guides provide model-specific wiring and diagnostic details. Manufacturer technical bulletins and HVAC trade resources explain gas pressure testing and electronic control diagnostics for advanced troubleshooting.

If the furnace continues to show Rheem Furnace Code 13 after following safe troubleshooting steps, contact an experienced, licensed HVAC technician to ensure reliable and safe heating performance.

Scroll to Top